Country Colombia
Industry Food
Media Type Liquids
Material Name Soda
Sensor NivoCapa® - NC 8100
Measuring Location Process hopper
Bin Characteristic Tank
Bin Material Stainless steel
Range / Bin size in m 300 mm
Sensor Installation Content - top mounting
Measurement Principle Capacitive
Material Characteristic Liquid water/oil based
DK value >4,0
Pressure <=0,8bar (11,6psi)
Temperature 80°C (176°F) - 150°C (302°F)
Hazardous Locations Not relevant
Atmosphere Steam
Moisture Not relevant
Buildup None
Corrosion Some
Vibration None
Electrostatic charge No
Visualization/Display Not relevant
Product Code NC8100A01AZZ1Y2 L=337
For more information about this product, please visit the following product page NivoCapa® - NC 8100
Reference of a successfully solved application NivoCapa 8000 in Caustic Soda and Brine