The store will not work correctly in the case when cookies are disabled.
Application Datasheet
Country |
China |
Industry |
Power plants |
Media Type |
Solids |
Material Name |
Fly ash |
Sensor |
RFnivo® - RF 3300 |
Measuring Location |
Process hopper |
Bin Characteristic |
Process hopper |
Bin Material |
Steel |
Sensor Installation |
Full detection - side mounting |
Measurement Principle |
Capacitive |
Material Characteristic |
Powder |
Density in g/l |
500g/l |
DK value |
3,0 - 4,0 |
Pressure |
0,8bar (11,6psi) ... 5bar (73psi) |
Temperature |
250°C (482°F) - 600°C (1112°F) |
Hazardous Locations |
Zone 20/21 |
Atmosphere |
Dusty |
Moisture |
Low |
Buildup |
Some |
Corrosion |
Some |
Vibration |
Some |
Electrostatic charge |
Not relevant |
Visualization/Display |
Not relevant |
Product Code |
RF3300C05LA2AZ2 L1=200mm, L2=100mm |
For more information about this product, please visit the following product page |
RFnivo® - RF 3300
|
Reference of a successfully solved application |
RF 3300 high temperature version for ash economizer process hopper
|
Back to result list