Application Datasheet

Country France
Industry Environment and recycling
Media Type Solids
Material Name Fly ash
Sensor RFnivo® - RF 3300
Measuring Location Process hopper
Bin Characteristic Silo (double chamber)
Bin Material Steel
Sensor Installation Full detection - top mounting
Measurement Principle Capacitive
Material Characteristic Powder
Density in g/l 400g/l
DK value 1,6 - 2,0
Pressure 0,8bar (11,6psi) ... 5bar (73psi)
Temperature 250°C (482°F) - 600°C (1112°F)
Hazardous Locations Zone 20/21
Atmosphere Dusty
Moisture Low
Buildup None
Corrosion None
Vibration None
Electrostatic charge Yes
Visualization/Display Not relevant
Product Code RF3300CN5LF3A11
For more information about this product, please visit the following product page RFnivo® - RF 3300