Continuous level measurement in bitumen
The Challenge
Reliable level measurement was required for the storage of bitumen. The heating required to maintain the bitumen at the desired temperature can cause temperature differences within the tank, while vapors and potential condensation can further affect measurement conditions. The integrated heating coils pose a particular challenge, as they can obstruct radar signals and cause unwanted reflections. This makes it difficult to accurately detect the actual bitumen level and maintain stable measurement under these challenging process conditions.
Our Solution
The NivoRadar® NR 7200 was used for continuous level measurement and specifically adapted to the installation conditions inside the bitumen tank. By aligning the sensor toward the center of the tank, a clear measurement path to the bitumen surface was established, minimizing the influence of the internal heating coils on the radar signals. This reduced unwanted reflections and ensured reliable, continuous level measurement of the bitumen.