Continuous Level Measurement in Niobium Ore Flotation
The Challenge
During the processing of niobium ore to produce niobium products, the crushed ore is mixed with water and special flotation reagents in a flotation tank. Air is introduced into the tank, causing the niobium-bearing minerals to attach to the air bubbles and rise to the surface, while other components of the ore largely remain in the liquid or sink to the bottom. This creates distinct phases within the tank. To monitor the separation process, the position of the interface between these phases needed to be measured.
Our Solution
To monitor the interface level, the NivoRadar® NR 7200 was installed in a bypass. The device detects changes in the height of a float inside the bypass, whose position follows the level in the flotation tank. This makes it possible to determine the position of the interface in the tank and monitor the separation process during niobium ore processing. The solution performed successfully and met the customer's requirements.