Electromechanical lot system
NivoBob® - NB 3100Medium Solids Process pressure -0,5 bar … +1,7 bar (-7.3 psi … +25 psi) Process temperature -40°C ... +250°C (-40°F … +482°F) -
Electromechanical lot system
NivoBob® - NB 3200Medium Solids Process pressure -0,5 bar … +1,7 bar (-7.3 psi … +25 psi) Process temperature -40°C ... +250°C (-40°F … +482°F) -
Electromechanical lot system
NivoBob® - NB 3300Medium Solids Process pressure -0,5 bar … +1,7 bar (-7.3 psi … +25 psi) Process temperature -40°C ... +80°C (-40°F … +176°F) -
Electromechanical lot system
NivoBob® - NB 3400Medium Solids Process pressure -0,5 bar … +1,7 bar (-7.3 psi … +25 psi) Process temperature -40°C ... +80°C (-40°F … +176°F) -
Electromechanical lot system
NivoBob® - NB 4100Medium Solids Process pressure -0,2 bar … +0,2 bar (-3.0 psi … +3.0 psi) Process temperature -40°C ... +80°C (-40°F … +176°F) -
Electromechanical lot system
NivoBob® - NB 4200Medium Solids Process pressure -0,2 bar … +0,2 bar (-3.0 psi … +3.0 psi) Process temperature -40°C ... +80°C (-40°F … +176°F) -
Capacitive sensor
NivoCapa® - NC 8100Medium Liquids Process pressure -1 bar … +35 bar (-14.5 psi … +511 psi) Process temperature -40°C ... +200°C (-40°F … +392°F) -
Radar sensors
NivoGuide® - NG 3100Medium Solids Process pressure -1 bar … +40 bar (-14.5 psi … +580 psi) Process temperature -40°C ... +200°C (-40°F … +392°F) -
Radar sensors
NivoGuide® - NG 8100Medium Liquids Process pressure -1 bar … +40 bar (-14.5 psi … +580 psi) Process temperature -40°C ... +200°C (-40°F … +392°F) -
Radar sensors
NivoGuide® - NG 8200Medium Liquids Process pressure -1 bar … +400 bar (-14.5 psi … +5800 psi) Process temperature -196°C … +450°C (-321°F … +842°F) -
Radar sensors
NivoRadar® - NR 3100Medium Solids Process pressure -1 bar … +3 bar (-14.5 psi … +43 psi) Process temperature -40°C ... +200°C (-40°F … +392°F)
Continuous level measurement
Unlike
, which can only detect a media level at a predefined point, level sensors detect the exact level of a medium in real time. The user is thus informed at all times about the current, percentage content of the container, which optimizes inventory management and reduces costs.There are different technologies for continuous level measurement such as
and as well as , all have advantages but also disadvantages depending on the application. For the selection, numerous process conditions have to be considered, which have to be mastered for the sensor technology. In addition, the requirements for bulk solids sensors differ from those for liquid sensors. For this reason, UWT offers a broad . This allows us to individually address their requirements to always provide them with the best possible solution.Typical challenges:
- Media type (e.g. bulk, powder, liquid, paste, etc.)
- Media properties (e.g. bulk density, conductivity, viscosity, etc.)
- Input conditions (e.g. tank material, tank geometry, installation position, installations within the tank, etc.)
- Process conditions (e.g. pressure, temperature, ambient conditions, explosion protection, hygiene requirements, etc.)